Mobile consumption measurement with VA 400 and DS 300 mobile
|
| | Special features • Easy installation of the consumption sensor under pressure • Consumption sensor usable from 1/2” to 12” (DN 300) • Depth scale for accurate installation • Inner diameter adjustable via keypad • All relevant measured data on one display: Current consumption in m3/h, m3/min, l/min, l/sec or cfm Total consumption in m3, l or cf, counter resttable • Data logger for 1 mio. measured values • USB interface • Software for evaluation
The DS 300 mobile is a 4 channel data recorder in a robust casing. It has two input channels for flow and dew point sensors and two input channels for analogue process signals. The internal rechargeable battery enables mains independent measurements for up to 4 hours. For long term measurements the mains supply is to be connected. The collected data can be transferred to a PC and analyzed with CS Soft What are the advantages of our consumption measuring technology? |
| | DS 300 mobile
| | | | Inputs:
| 2 digital inputs VA 400 resp. FA 410 2 analogue inputs for pressure sensors, clamp-on ammeters, temperature sensors | | | Dimensions: | 280 x 230 x 155 mm | | | Weigth: | 2400 g | | | Power supply: | 100 ...240 VAC, 50-60 Hz, internal rechargeable batteries (4 h mains independent measurements) | | | Interface: | USB | | | Operating temperature: | 0 ...50°C | | | Transport temperature: | -20 ...70°C | | | Data logger: | 1 million measured values, start/stop time, measuring rate freely adjustable | | | Consumption sensor VA 400-Max
| | | | Measuring range:
| 4 ...1198 m3/h ((according to a tube innerØ of 53,1 mm, 20°C and 1000 mbar) Measuring ranges for other inner diameters see the instruction manual | | | Measuring medium: | Air, gases( non explosive) | | | Measuring principl: | calorimetric measurement | | | Operation pressure: | up to 50 bar | | | Operation temperature: | -30...110 °C sensor tube, -30...70°C housing | | | Length sensor connection cable : | 5 m | | | Dimensions: | Dimensional drawing VA 400 |
| | DESCRIPTION
| ORDER-NO.
| | | Set mobile consumption measurement DS 300 mobile/VA 400-Max., consisting of: | | | | DS 300 mobile with Data logger for 1 million measured values, 2 digital inputs, 2 analogue inputs | 0500 3225 | | | Consumption sensor VA 400-Max., probe length 220mm, incl. certificate and 5m connection cable | 0695.0122 | | | Options:
| | | | Display for VA 400 | Z695 4000 | | | HighSpeed version VA 400 (224 m/s) | Z695 4002 | | | Probe length 120 mm | ZSL 0120 | | | Probe length 160 mm | ZSL 0120 | | | Probe length 220 mm | ZSL 0160 | | | Probe length 300 mm | ZSL 0300 | | | Probe length 400 mm | ZSL 0400 |
| | DESCRIPTION ACCESSORIES
| ORDER-NO. | | | 5 point precision calibration with ISO certificate | 0699 3396 | | | CS Service Software for FA/VA 400 sensors incl. PC connection set, USB adapter and interface adapter to sensor as well as CS Soft Professional software | 0554 7010 |
 |
|
|
|
| VA 400 with Display
| | | | |
|