Dew point sensor FA 300 Ex
|


| | Special features • Robust design • Pressure-tight up to 300 bar • Long-term stable humidity sensor,approved for years • 4...20 mA analogue output in 2-wire technology • Further parameters adjustable via software: % RH, g/m3, mg/m3, ppm V/V, g/kg • CS Service Software for data storage and calibration (for use in non-explosive area)
FA 300-2 Ex measures the dew point resp. the pressure dew point in explosive areas of Zone 1. Protection class: FA 300-2 Ex: II 2G EEx ia II C T4 With the Atex approval for Zone 1 the established dew point measuring instruments FA 300-2 Ex can now be used in explosive areas of the industry as well. FA 300-2 Ex may only be used in connection with approved Ex-rated power supplies or safety barriers or galvanic separating elements with max.: U0 = 30 V max. I0 = 100 mA max. P0 = 1 W max.
Data sheet FA 300 Ex (pdf/ 69KB) |
| | Measuring range: | -80...20 °Ctd = 4 ...20 mA | | | Accuracy:
| ± 0.5 °C at -10...50 °Ctd, typical ± 2 °C at -40 °Ctd | | | Pressure range: | -1...300 bar | | | Power supply: | 24 VDC (10...30 VDC) | | | Protection class: | IP 65 | | | EMC: | according to DIN EN 61326 | | | Operating temperature: | -20...70 °C | | | Storage temperature: | -40...80 °C | | | Output: | 4...20 mA in 2-wire technology | | | Connection: | DIN 4650, 4-pole | | | Burden for analogue output: | < 500 Ohm | | | Screw-in thread: | G1/2 stainless steel | | | Housing material: | Polycarbonate | | | Sensor protection: | Sintered filter 50μm, stainless steel |
| | DESCRIPTION
| ORDER-NO.
| | | FA 300-2 Ex pressure dew point meter | 0699 3070 | | | Intrinsically safe power supply, safety barriers | 0554 3071 | | | Option: | | | | Special scaling analogue output to other humidity parameters: % RH g/m3, mg/m3, ppm V/V, g/kg | 0699 4004 |
| | DESCRIPTION ACCESSORIES
| ORDER-NO. | | | High-pressure measuring chamber up to 350 bar | 0699 3590 | | | CS Service Software FA incl. PC connection set and CS Soft Professional | 0554 2002 | | | Precision calibration at -40°Ctd including ISO certificate | 0699 3396 | | | Precision calibration at 0 °C and 10 °Ctd including ISO certificate | 3200 0003 | | | Control and calibration set 11.3 % RH | 0554 0002 | | | Control and calibration set 33 % RH | 0554 0004 | | | Control and calibration set 75.3 % RH | 0554 0005 |
|