Dew point sensor FA 300 Ex

Description

Taupunktsensor FA 300 Ex


Non-explosive area FA 300 Ex
 

Special features
• Robust design
• Pressure-tight up to 300 bar
• Long-term stable humidity sensor,approved for years
• 4...20 mA analogue output in 2-wire technology
• Further parameters adjustable via software:
  % RH, g/m3, mg/m3, ppm V/V, g/kg
• CS Service Software for data storage and calibration
  (for use in non-explosive area)

FA 300-2 Ex measures the dew point resp. the pressure dew point in explosive areas of Zone 1.
Protection class: FA 300-2 Ex: II 2G EEx ia II C T4
With the Atex approval for Zone 1 the established dew point measuring instruments FA 300-2 Ex can now be used in explosive areas of the industry as well.
FA 300-2 Ex may only be used in connection with approved Ex-rated power supplies or safety barriers or galvanic separating elements with max.:
U0 = 30 V max.
I0 = 100 mA max.
P0 = 1 W max.

Data sheet FA 300 Ex (pdf/ 69KB)

Technical Data

 Measuring range: -80...20 °Ctd = 4 ...20 mA
 Accuracy:
± 0.5 °C at -10...50 °Ctd,
typical ± 2 °C at -40 °Ctd
 Pressure range: -1...300 bar
 Power supply: 24 VDC (10...30 VDC)
 Protection class: IP 65
 EMC: according to DIN EN 61326
 Operating temperature: -20...70 °C
 Storage temperature:-40...80 °C
 Output:4...20 mA in 2-wire technology
 Connection:DIN 4650, 4-pole
 Burden for analogue output:< 500 Ohm
 Screw-in thread:G1/2 stainless steel
 Housing material: Polycarbonate
 Sensor protection:Sintered filter 50μm, stainless steel

Order Numbers

 DESCRIPTION
ORDER-NO.
 FA 300-2 Ex pressure dew point meter0699 3070
 Intrinsically safe power supply, safety barriers0554 3071
 Option: 
 Special scaling analogue output to other humidity parameters: % RH g/m3, mg/m3, ppm V/V, g/kg 0699 4004

Accessories

 DESCRIPTION ACCESSORIES
ORDER-NO.
 High-pressure measuring chamber up to 350 bar 0699 3590
 CS Service Software FA incl. PC connection set and CS Soft Professional0554 2002
 Precision calibration at -40°Ctd including ISO certificate0699 3396
 Precision calibration at 0 °C and 10 °Ctd including ISO certificate 3200 0003
 Control and calibration set 11.3 % RH 0554 0002
 Control and calibration set 33 % RH0554 0004
 Control and calibration set 75.3 % RH 0554 0005 


 Please ask here for more information