Dew point set FA 410 for membrane and adsorption dryers

Description

Dew point set FA 410  

Special features
• System ready for plug-in: everything completely wired
• No time-consuming studying of the instruction manual
• 2 alarm contacts (230 VAC, 3 A)
• pre- and main-alarm freely adjustable
• Optical alarm: Red flashing
• Parallel indication % RH, °C, °Ctd
• USB- Schnittstelle zum PC
• Data logger for 1 mio. measuring values (optional)

Data sheet dew point set FA 410 pdf (82KB)

 

Technical Data

 DS 300
 
 Dimensions wall mounting:118 x 115 x 93 mm
 Dimensions panel mounting:92 x 92 mm
 Inputs:2 digital inputs for FA 410 resp. VA 400
 Power supply:100 ...240 VAC, 50-60 Hz
 Interface:USB
 Operating temperature:0 ...50°C
 Alarm output:2 relays (230 VAC, 3A)
 Length power cable: 3 m
 Dew point sensor FA 410
 
 Measuring range: -80...20 °Ctd resp. 0...100 %RH
 Pressure range: -1...50 bar
 Operating temperature: -20...70 °C
 Connection: M12, 5-pole
 Screw-in thread:G1/2”
 Dimensions: Ø30 mm, length 130 mm
 Length sensor cable: 5m

Order Numbers

 DESCRIPTION
ORDER-NO.
 Dew point set FA 410 for adsorption dryers (-80...20 °Ctd) consisting of:0600 0410
 Multifunction measuring instrument DS 300 0500 3000
 FA 410 dew point sensor -80 ...20°Ctd0699 0410
 Standard measuring chamber up to 16 bar0699 3390
 Options:
 
 Integrated data logger for 1 million measured values Z500 3001
 Alarm unit mounted at wall housing Z500 0003
 Alarm unit for external mounting with 5 m cableZ500 0004
 Special version FA 410 up to 350 bar 0699 4003
 Output in mg/m3, g/kg, oder %RH, special scaling 4...20 mA 0699 4004

Accessories

 Description Accessories
ORDER-NO.
 Connection cable FA/VA series 400, 5m with M12 plug, open ends0553 0104
 Connection cable FA/VA series 400, 5m with M12 plug, open ends0553 0105
 Alarm cable, length: 5m0553 0106
 Alarm cable, length: 10m0553 0107
 High-pressure measuring chamber up to 350 bar (in conjunction with FA 410 for 350 bar) 0699 3590
 Measuring chamber for atmospheric dew point0699 3690
 Measuring chamber for respiratory air bottles up to 350 bar 0699 3790
 Measuring chamber for granulate dryers0699 3490
 CS Soft Professional for data evaluation incl. USB interface 0554 7010
 CS Service Software VA/FA incl. PC connection set and CS Soft Professional0554 2005
 Precision calibration at -40°Ctd including ISO certificate0699 3396
 Precision calibration at 0 °C and 10 °Ctd including ISO certificate  3200 0003
 Control and calibration set 11.3 % RH 0554 0002
 Control and calibration set 33 % RH0554 0004
 Control and calibration set 75.3 % RH 0554 0005 

Photos

Standard measuring chamber High-pressure measuring chamber Measuring chamber for atmospheric Measuring chamber for respiratory air bottles Measuring chamber for granulate dryers 
Standard
measuring chamber
 High-pressure measuring chamber Measuring chamber for atmospheric
dew point
 Measuring chamber for respiratory air bottles Measuring chamber for granulate dryers 
Control and calibration set         
Control and calibration set
         


 Please ask here for more information