VA 420 Stainless steel 1.4404

Article no: 0695 1

Intelligent solutions for accurate consumption measurement for compressed air and gases

Application-technological features of the consumption counters VA 420:

  • Easy and affordable installation
  • Units freely selectable via keypad m³/h, m³/min, l/min, l/s, kg/h, kg/min, kg/s, cfm
  • Compressed air counter up to 1,999,999,999 m³. Resettable to "zero" via keypad
  • Analogue output 4...20 mA, pulse output (galvanically seperated)
  • High measuring accuracy also in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Gas types adjustable via software (nitrogen, oxygen, CO2, nitrous oxide, argon)


Application range of VA 420:

  • Compressed air balancing, compressed air consumption measurement
  • Leakage air / leak rate determination
  • Mobile compressed air measurement in front of single machines / plants
  • Flow measurement of process gases like e. g. nitrogen, CO2, oxygen, argon, nitrous oxide
  • Flow measurement at nitrogen generators

Note

We are always working on the improvement of our products!

For this reason our consumption counters VA 420 will have a slot joint in future.

Despite this change the shipment of measuring sections with pin connection will continuously be granted. So an

* Required Fields

Add to your enquiry list

Parameters:

m³/h, l/min (1000 mbar,
20°C) in case of compressed
air resp. Nm³/h,
Nl/min (1013 mbar, 0°C
in case of gases)

Adjustable via
keypad:

m³/h, m³/min, l/min, l/s,
ft/min, cfm, m/s,
kg/h, kg/min

Meas. principle:

calorimetric measurement

Sensor:

2x silicium chip

Meas. medium:

air- gases

Gas types adjustable
via software:

air, nitrogen, argon,
nitrous oxide, CO2, oxygen

Accuracy:

± 1.5% of m.v., ± 0.05% of f.s.
On request: Special calibration
via 5 point ISO calibration certificatet

Operation temp.:

-30...80°C

Operating press.:

up to 16 bar
Optional up to PN 40

Analogue output:

4...20 mA for m³/h resp. l/min

Pulse output:

1 pulse per m³ resp. per
liter galvanically seperated

PC connection:

SDI interface

Power supply:

24 VDC smoothed ± 15%

Burden:

< 500 Ohm

Housing:

polycarbonate

Meas. section:

stainless steel, 1.4303
or 1.4404

Mounting thread meas. section:

R 1/4", R 1/2", R 3/4"
R 1", R 1 1/4", R 1 1/2", R 2"
external thread

Feedback