PRODUCTS  »  Dew Point  »  FA 500 - Dew point sensor with integrated display and alarm relay

FA 500 - Dew point sensor with integrated display and alarm relay

Dew point sensor FA 500 from -80 to 20°Ctd

FA 500 is the ideal dew point sensor with integrated display and alarm relay for refrigeration, membrane and desiccant driers.

Special features:

  • NEW: Modbus-RTU interface
  • NEW: Higher resolution of sensor signal caused by the improved evaluation electronics
  • NEW: Sensor diagnosis on site with a portable device or CS Service Software
  • Integrated display
  • Threshold value adjustable via keypad alarm relay (max. 60 VDC, 0,5 A)
  • Pressure-tight up to 350 bar (special version)
  • Extreme long-term stability
  • Quick response time
  • 4...20 mA analogue output
  • 2 versions: Refrigeration driers and desiccant driers

Easy operation via keys at the display

  • The integrated display shows the dew point in big figures as well as further humidity parameters on two more display pages. By means of the arrow key it can be browsed between the display pages.
  • The alarm threshold value for the integrated relay can be entered via the keys. Apart from the alarm threshold it is also possible to enter the hysteresis freely.
  • The 4...20 mA analogue output can be scaled freely resp. also allocated to one further parameter, e.g. g/m³.
  • If requested the sensor can also reckon back from the measured pressure dew point to the atmospheric dew point upon entering the system pressure of the compressed air plant and the reference pressure (atmospheric pressure).

FA 500 - Dew point sensor with integrated display and alarm relay

Related products

Dew point sensor for residual moisture measurement - FA 510 / FA 515

FA 510/515 - Dew point sensor for adsorption dryers

For residual moisture measurement after desiccant dryers/ membrane dryers from -80 to 20°Ctd. New: with Modbus-RTU interface.

Dew point measurement set for desiccant dryers - DS 52 set

Dew point measurement DS 52-set for desiccant dryers

with the digital process meter DS 52 and the dew point sensor FA 510 with a measuring range from -80 to 20°Ctd.

Dew point sensor for refrigeration dryers - FA 510 / FA 515

FA 510/515 - Dew point sensor for refrigeration dryers

Dew point measurement from -20 to 50°Ctd. New: with Modbus-RTU interface.

Dew point measurement set for refrigeration dryers - DS 52 set

Dew point measurement DS 52-set for refrigeration dryers

with the digital process meter DS 52 and the dew point sensor FA 510 with a measuring range from -20 to 50°Ctd.

Suitable accessories

Standard dew point measuring chamber for compressed air up to 16 bar

Standard measuring chamber

for compressed air up to 16 bar

High-pressure dew point measuring chamber for compressed air up to 350 bar

High-pressure measuring chamber

for compressed air up to 350 bar

Control and calibration set for dew point sensors

Control and calibration set for dew point sensors

is screwed onto the dew point sensor and therefore enables an easy and low-priced possibility for on-site control and calibration down to -20°Ctd.

Measuring chamber stainless steel 1.4304 for dew point measurement

Measuring chamber stainless steel 1.4305, for dew point measurement

in gases / air up to 100 bar