FA 510/515 - Dew point sensor for adsorption dryers

Monitoring a Desiccant dryer is crucial to increase Energy efficiency, ensure product quality, prevent damage to machinery, identify maintenance needs and realise cost savings. This contributes to the smooth functioning of compressed air systems in various Industrial applications.

The sensor technology and evaluation electronics of our sensors have undergone continuous improvement. This implies an increased precision at varying ambient temperatures and a higher signal resolution of the sensor. Similar to their predecessors, the new Dew point sensors are characterised by long-lasting, stable and reliable measurement results. The sensor element is insensitive to condensation and is protected from direct contact with contaminated Particles by the stainless steel sintered cap.

Details

  • Ideal for all types of Desiccant dryers with a Measuring range of -80...+20°Ctd.
  • Measuring independent of gases, also suitable for other non-corrosive gases
  • Compact design, ideal for dryer installations
  • Robust design, protection class IP 66
  • Condensation-resistant sensor element
  • Long-term stability and drift-resistant, therefore optimised calibration intervals
  • Fast adaptation time, especially from dry to wet conditions
  • BSP, NPT or UNF thread
  • 4...20 mA analogue output (two- or three-wire technology) and Modbus RTU (RS 485) interface
  • Measured values available in various units, Pressure dew point [°Ctd], Temperature [°C], Rel. humidity [%rh], Abs. humidity [g/m³], Degree of humidity [g/kg], Humidity fraction V/V [ppmV/V], Water vapour partial pressure [hPa], Atmospheric dew point [°Ctd.atm]
  • Sensor diagnostics on site with Handheld device or CS Service Software

Similar products

FA 500 - Dew point sensor with integrated display and alarm relay

Dew point sensors for various types of dryers with integrated Display and alarm relay.

More

FA 510/515 - Dew point sensor for refrigeration dryers

for measuring residual moisture from -20 to 50°Ctd. New: With Modbus RTU interface.

More

Dew point measurement DS 52-set for desiccant dryers

with the process display DS 52 and the Dew point sensor FA 510 with a Measuring range of -80...20°Ctd.

More

Dew point measurement DS 52-set for refrigeration dryers

with the process display DS 52 and the Dew point sensor FA 510 with a Measuring range of -20...50°Ctd.

More

Accessories

Standard measuring chamber

For compressed air up to 16 bar

More

Control and calibration set for dew point sensors

is screwed onto the Dew point sensor and thus provides a simple and inexpensive control and adjustment option.

More