OIL CHECK 512 – Residual oil content sensor for compressed air, oil class 2

The OIL CHECK 512 continuously monitors the gaseous oil content in compressed air and other gases, either centrally within the compressed air treatment system or directly at the point of use. It is suitable for applications where Class 1 purity is not required.

Benefits at a glance:

  • PID sensor principle – indicative measurement in accordance with ISO 8573-5:2025
  • 4 calibration points, 1 of which is within Class 2 – the monitor is calibrated where it matters for the application: at the transition to Class 3
  • Very simple installation and maintenance, even under pressure – ensures measurement availability
  • Low cross-sensitivity to humidity and ethanol – ensures reliable measured values
  • Long-life light source – average operating life of 15,000 hours
to the request

The product has been added to the request.
to the request

Details

Description of the measuring instrument:

The OIL CHECK 512 Point-of-Use Monitor is an at-line sensor. It continuously samples a small portion of the flow and measures the residual oil content present in the vapour-phase.

To reliably monitor critical processes and plant components, measurement after media treatment is often insufficient. Situations may also arise within the distribution network whereby oil components are introduced into the system. The OIL CHECK 512 helps to detect such situations by identifying changes in the concentrations of gaseous oil components. In this way, it helps to protect critical processes.

  • Indicative measurement in accordance with ISO 8573-5:2025: Indicative measurement in accordance with ISO 8573-5 provides transparency exactly where it matters most in operation: directly at the point of use or centrally within the compressed air system, without having to wait for laboratory results. It continuously monitors residual oil levels and immediately highlights changes in the process, ensuring greater safety and a faster response. It focuses on gaseous components, particularly oil vapours, thereby complementing quantitative laboratory analysis with a practical online monitoring system. This provides operators with a powerful tool for consistent compressed air quality, reliable processes and operational safety.
  • 4 calibration points, 1 of which is within Class 2: The most important factor for monitoring the purity grade is the correct calibration of the measuring system. The limit value specified in ISO 8573 for Class 2 is 0.1 mg/m³. This corresponds to a volume concentration of 25 ppb. That means 25 particles per billion. The OIL CHECK 512 is calibrated with one adjustment point in Class 2. Another calibration point is situated precisely at the transition to Class 3, exactly where it is important for the transition to Class 2. Calibration at two further points ensures that even high residual oil readings can be measured reliably.
  • Very simple installation and maintenance, even under pressure: the OIL CHECK 512 is designed for quick replacement in the field. Thanks to its compact design, low weight, quick coupling and M12 connector, the sensor is easy to fit and remove. This means it can be quickly replaced with a spare sensor for servicing or recalibration. Measurement thus remains available with minimal effort.
  • Low cross-sensitivity to humidity and ethanol: Cross-sensitivity to gases that are not target gases for oil vapour measurement can increase the measured value even when there is no relevant contamination present in the measurement gas. The OIL CHECK 512 has been specifically developed to minimise cross-sensitivity to the two commonly occurring interfering gases, humidity and ethanol. This improves the reliability of the measured values.

Frequently Asked Questions (FAQ) on residual oil measurement using the OIL CHECK 512

VDMA 15390-1:2014-12 specifies Class 2 applications in many industrial sectors as a typical cleanliness requirement, including in 

  • petrochemicals
  • tobacco processing
  • textile, paper and printing industries
  • chemical industry
  • rubber and plastics industry
  • Surface finishing
  • Mechanical and plant engineering, as well as electrical engineering and electronics. 

In such applications in particular, a one-off test is often insufficient. Continuous monitoring detects changes in the residual oil content at an early stage and documents whether the central treatment system is maintaining the required compressed air quality on a long-term basis.

VDMA 15390-1:2014-12 emphasises that the purity of compressed air at the end-user’s premises depends not only on centralised treatment, but also on the compressed air network and any decentralised treatment. This is precisely why point-of-use measurement makes technical sense: it indicates the compressed air quality precisely where it is actually relevant to the process or the machine. This is particularly important when a machine manufacturer specifies a particular compressed air quality and, in case of doubt, the operator must provide reliable documentation to rule out compressed air as a source of fault.

The OIL CHECK 512 has been developed as an at-line monitor.

  • Design: Thanks to its compact design and low weight, it can be integrated very easily into existing systems. It can also be easily incorporated into the design of new machines.
  • Data transmission: With a Modbus RTU connection and a 4 … 20 mA connection, the OIL CHECK 512 features the essential interfaces for field devices.

As the vapour-phase residual oil content increases, so does the risk of oil aerosols. These can contaminate the OIL CHECK 512. It is therefore not advisable to extend the measuring range.