Every physical measuring principle has its own strengths. Our range of measurement systems allows you to choose based on gas type, gas quality, measuring range, pressure and installation conditions. We can help you find the right method and the appropriate design.
Thermal mass flow measurement:
Thermal sensors determine the mass flow rate based on the heat transferred from a heated sensor element to the gas. Given a known gas type and appropriate calibration, they provide the standard volumetric flow rate directly, without the need for additional pressure and temperature compensation. The method measures total consumption as well as small residual consumption rates and leak rates. The VA series offers insertion sensors and instruments with an integrated measuring section for this purpose. Depending on the version, the VA 550 measures from 0.05 m/s with a measuring span of up to 1:1000; the high-speed version extends up to 224 m/s (both velocity values are based on 20 °C and 1000 mbar absolute).
Differential pressure flow measurement and Venturi technology:
The VD series dynamic pressure probes perform the calculation of flow rate from differential pressure, pressure, temperature and gas density. In the VD series and the CMM 500, a high-precision differential pressure sensor ensures a low measurement start point and a wide measuring span. The VD series offers solutions for compressor measurements, high pressures, as well as wet compressed air and industrial gases. Suitable models can be configured using gas data for various gases and known gas mixtures, without the need for gas-specific actual gas adjustment. With the VD and CMM series, zero-point adjustment can be carried out directly on site. The CMM 500 utilises the Venturi principle to perform measurement of compressor capacity on test rigs and during operation. As a compressed air meter, it also provides the measurement data for consumption-based billing – for example, as part of ‘compressed air as a service’.
vortex flow measurement:
Vortex flow sensors detect the frequency of vortices behind a flow restrictor. The VU 570 detects these vortices using ultrasound; the VX 570 utilises piezoelectric detection with reference vibration measurement. This method is particularly suitable for industrial gases and gas mixtures, even where the composition varies. The VX 570 also covers vapour and liquid applications. Gas density is required for mass flow calculation. The VU 570 measures pressure and temperature as standard, whilst the VX 570 does so in the version with an integrated pressure and temperature sensor – external sensors or an additional flow computer are not required for this.
Clamp-on ultrasound:
Clamp-on sensors determine the flow based on the difference in transit time of ultrasonic signals travelling with and against the flow. The VC 600 measures from the outside, without opening the pipe and without causing any additional pressure drop. It detects the flow direction and is suitable for retrofit measurements and temporary measurements. Pressure and temperature are taken into account for conversion to the standard volumetric flow rate; external sensors can be connected.
| measuring principle | standard volumetric flow rate | Strengths and measurement tasks | Installation | Products |
| Thermal mass flow rate | Mass flow rate directly; standard volumetric flow rate with appropriate gas reference | Leak rates, total consumption, small residual consumption and base load; very low flow velocities and wide measuring span | Insertion sensor or integrated measuring section | VA 526, VA 500, VA 520, VA 550, VA 570, VA 521, VA 525 |
| Differential pressure / Venturi | Calculated using integrated pressure and temperature measurement and gas density; no external sensors required | Compressor capacity, wet compressed air, high pressures; wide measuring span from low flow rates up to very high flow velocities; reference measurements; flexible configuration for gases and known gas mixtures | Insertion sensor, integrated measuring section or Venturi measuring section | VD 500, VD 520, VD 550, VD 570, CMM 500 |
| Vortex | Calculated using integrated pressure and temperature measurement; gas data per measured variable | Industrial gases and gas mixtures; the VX 570 also measures vapour and liquids | Measuring section with thread or flange | VU 570, VX 570 |
| Clamp-on ultrasonic ultrasound | Calculation using pressure and temperature; gas data per measured variable | Retrofit without opening the pipe, temporary measurements and flow direction detection; low flow velocities, even in high-pressure pipes | Mounted externally on the pipe | VC 600 |