Author: Florian Buchner
Role: Product Manager, Flow Measurement Technology
Area of expertise: Thermal flow measurement, industrial gas measurement and energy monitoring
Last updated on 14 October 2026
At a glance: Thermal mass flowmeters from CS INSTRUMENTS measure natural gas consumption without any moving parts and output the standarized volume flow directly – for consumption monitoring, cost centre management and energy management. The VA 550 and VA 570 are available, depending on the version, with ATEX approval or DVGW approval for natural gas (up to 16 bar).
When is it worth using a thermal mass flow meter?
In industrial natural gas networks, turbine meters, piston gas meters and quantometers are most commonly used; users sometimes refer to these generally as impeller meters. If low flow rates are not measured accurately, moving measuring parts require maintenance, or digital consumption data is lacking, a thermal mass flow meter for natural gas is an alternative worth considering.
How turbine-wheel and rotary-piston gas meters work – and where their limitations lie. In a turbine-wheel gas meter, the gas flow strikes a mechanically mounted turbine wheel and drives it; the rotational speed is proportional to the flow velocity and, via the known pipe cross-section, to the volume flow. In a rotary piston gas meter, the pressure difference drives rotors within a measuring chamber; each rotor encloses a precisely defined volume of gas and conveys it on to the consumer. The usable measuring range of mechanical gas meters depends heavily on the design, size, operating pressure and model: simple quantometers often operate with significantly lower dynamic range than a thermal sensor.
The inherent limitations of both designs lie in their moving parts: Bearings age due to dirt or abrasion and cause measurement deviations; exceeding the measuring range can cause bearing damage; some bearings must be lubricated regularly – something that is easily neglected in practice –; contaminated gas leads to greater deviations, and cleaning is virtually impossible; in the case of rotary piston gas meters, there is also a design-related pressure loss.
| Criterion | Turbine wheel meter / Quantometer | Thermal mass flow meter |
| Measured variable | Typically, operating volume | Mass flow, from which standard volume is derived (e.g. in accordance with DIN 1343, 1013.25 mbar; 0°C) |
| Moving parts | Yes | No |
| Low flows | Depending on design | High dynamic range possible (up to 1:1000) |
| Pressure drop | High | negligibly low |
| Standard volume | Volume converter + pressure and temperature compensation required | direct, provided parameters are set correctly |
| Digital integration | Depends on the device | Depending on the model: Modbus TCP, Modbus RTU, M-Bus, IO-Link, HART, etc. |
| Retrofitting of large pipelines | Complex | Insertion type sensor possible |
Measuring partial load and peak flow: The VA 550 and VA 570 offer a measuring span of up to 1:1000. The actual minimum and maximum flow rates (Qmin/Qmax) remain the decisive factors. With the VA 550 and VA 570, the measuring range can be selected to suit the application (Low Speed, Standard, Max and High Speed). Further advantages of the thermal principle include the negligible pressure loss and the ability to measure even the smallest consumption rates: the VA 550 and VA 570 are very often used in large pipe cross-sections with low gas consumption, where mechanical gas meters reach their limits.
Avoiding rotor wear: The thermal principle measures the heat emitted by a heated sensor – without rotor bearings and with minimal additional pressure loss. The sensors (heater and temperature sensor) are designed for harsh industrial environments and housed in a thin, robust stainless-steel tube: no bearings, no wear, easily accessible and simple to clean if soiled. The meters are very robust and virtually maintenance-free.
Outputting standard volume directly: Mechanical gas meters are generally operating volume meters; conversion to standard volume is carried out via external volume converters fitted with additional pressure and temperature sensors. To achieve the required accuracy, these sensors must be highly precise and be located within or close to the meter – their measurement errors are added to the meter’s accuracy, which is usually specified in operating volume. The VA 550 and VA 570 measure the thermal mass flow rate and, given appropriate gas parameterisation and specified reference conditions, output the standarized volume flow directly; a separate flow converter with additional pressure and temperature measurement is not required for this. For comparisons, the reference conditions must be the same (e.g. 0 °C; 1,013.25 mbar (a) in accordance with DIN 1343 – also referred to as standard m³/Nm³); for kWh calculations, the calorific value must also be taken into account.
Operating volume or standard volume: why the difference is crucial for natural gas
At elevated operating pressure, the standard volume is greater than the operating volume – in proportion to the absolute pressures, with an additional correction for temperature. If an operating volume is incorrectly reported as a standard volume or processed as such, the actual gas consumption is systematically underestimated, and the kWh balance mirrors this error exactly, as it depends linearly on the volume:
| Operating overpressure | Ratio of standard volume to operating volume (ideal gas, excluding temperature term) | Underestimation in the event of confusion |
| 50 mbar | ≈ 1.05 | ≈ 5 % |
100 mbar | ≈ 1.10 | ≈ 10 % |
| 500 mbar | ≈ 1.49 | ≈ 33 % |
| 1 bar | ≈ 1.99 | ≈ 50 % |
| 4 bar | ≈ 4.95 | ≈ 80 % |
Added to this is the temperature reference: there is a difference of around 7 per cent between a gas temperature of 20 °C and the standard reference temperature of 0 °C. These values are provided for illustrative purposes using an ideal gas; for billing or highly accurate state conversion, factors such as temperature, gas composition and compressibility must be taken into account (DVGW Regulation G 685). The most common source of error in energy balances is not measurement precision, but an unnoticed incorrect volume reference.
Where is thermal natural gas metering particularly worthwhile?
In main and distribution pipes, a point of measurement continuously monitors the total consumption of a building, area or boiler house – for larger existing pipework, the VA 550 is a useful option as an insertion type sensor, as there is no need to install a complete in-line measuring section in the nominal diameter. Directly upstream of individual consumers (boilers, burners, production plant), it becomes clear which consumer requires how much natural gas and when – the basis for load profiles and cost centres. The most informative approach is the combination: main metering plus sub-meters shows total consumption and its distribution.
How are the measured values fed into the energy management system?
With many existing mechanical meters already installed, consumption data is transmitted solely via a pulse output; modern electronic meters can also offer digital interfaces. Depending on the version ordered, the VA 550 and VA 570 can be integrated directly into the central control system or energy monitoring software via Modbus TCP over Ethernet (flow, total consumption, gas temperature); an RTU/TCP gateway is not required. Optional Power over Ethernet combines data transmission and power supply in a single network cable – this reduces installation effort, particularly where there are multiple points of measurement. Alternatively, Modbus RTU, 4…20 mA, pulse, M-Bus, IO-Link or HART are available.
Advantages during installation, maintenance and recalibration
Retrofitting the VA 550 as an insertion type sensor: The sensor is installed via a suitable process access point or ball valve. A depth scale and defined orientation ensure a reproducible sensor position. The VA 550 is designed for operating pressures up to 50 bar (DVGW version up to 16 bar); installation and removal whilst under pressure are carried out via a ½" ball valve with a retaining ring.
VA 570 as an in-line solution: During cleaning or recalibration, the measuring section remains in the pipe – only the sensor unit is removed. The sensor is sent in for recalibration; replacement sensors can be fitted for the duration of the calibration, ensuring there is no interruption to operations.
Operation: On the VA 550 and VA 570, optical keys allow settings to be adjusted without opening the housing – the operation of both devices is identical. Digital device and status information (Modbus registers) assist with troubleshooting and handover documentation.

Practical example: From consumption value to process parameter
In a boiler application, 330 Nm³/h of natural gas and 5,000 kg/h of vapor are measured. The boiler efficiency is calculated from gas consumption, heating value and steam data – 84 per cent in the documented example. In this way, a simple consumption measurement is transformed into a reliable indicator of efficiency and maintenance. (→ Steam boiler application report)
Which natural gas flow meter is suitable for this application?
| sensor | Classification |
| VA 570 | In-line with integrated measuring section – flanged versions with nominal diameter 15–80, threaded versions ½"–2"; operating pressure 16 bar (special version 40 bar); Measuring head removable for calibration; measuring section remains in the pipe with a sealing cap; ATEX/IECEx or DVGW compliant, depending on the version. |
VA 550 | Insertion type sensor for larger and existing pipes – particularly suitable for retrofitting via a suitable measurement connection; ATEX/IECEx or DVGW compliant, depending on the version. |
What applies to ATEX and gas installations?
The VA 550 and VA 570 are available with ATEX/IECEx approval, depending on the variant; the Ex marking for these variants, as stated in the data sheet, is: ATEX II 2G Ex db IIC T4 Gb (gas) and II 2D Ex tb IIIC T90 °C Db (dust); IECEx Ex db IIC T4 Gb / Ex tb IIIC T90 °C Db. In the Ex version, the maximum medium temperature is 120 °C and the protection class is IP 65. The EU-type examination certificate is available in the downloads section. It is the operator’s responsibility to verify suitability for the specific explosion-protected area. CS INSTRUMENTS provides technical data sheets and Ex certificates for this purpose, but does not offer advice regarding zone classification or suitability for a specific installation.